Endurance Charger technical specifications

Charger Panel specifications

Specification 8 x 5 A panel 4 x 15 A / 8 x 15 A panel
Dimensions 795 (W) x 410 (H) x 140 (D) mm 4 x 15 A: 555 (W) x 410 (H) x 140 (D) mm; 8 x 15 A: 1010 (W) x 410 (H) x 140 (D) mm
AC connection IEC 60309 2P+E IEC 60309 2P+E
Input power 180-265 VAC, 45-65 Hz, 15 A 180-265 VAC, 45-65 Hz, 15 A
Battery connection Anderson SB50 grey connector Anderson SB50 grey connector
Operating temperature -40°C to +50°C; full rated output up to 30°C -40°C to +50°C; full rated output up to 30°C
Maximum non-condensing humidity 95% 95%

Individual charger specifications

Specification 12 V 5 A charger 12 V 15 A charger
Efficiency 94% 94%
Standby consumption 0.5 W 0.5 W
Maximum output current in Normal mode 5 A 15 A
Recommended maximum battery capacity 150 Ah 150 Ah
Minimum lead-acid battery capacity in Normal mode 50 Ah 50 Ah
Temperature compensation 16 mV/°C 16 mV/°C
Charge algorithm Seven-stage adaptive Seven-stage adaptive
Back-current drain 0.7 Ah/month (1 mA) 0.7 Ah/month (1 mA)
Protection Reverse polarity, output short circuit and overtemperature Reverse polarity, output short circuit and overtemperature

Charging voltages

Mode Absorption Float Storage Recondition
Normal 14.4 V 13.8 V 13.2 V 16.2 V
High 14.7 V 13.8 V 13.2 V 16.5 V
Li-ion 14.2 V 13.5 V 13.5 V Not applicable

For traffic signal batteries, use Normal mode. Do not use High or Li-ion mode.

Standards

  • Safety: EN 60335-1 and EN 60335-2-29
  • Emissions: EN 55014-1, EN 61000-6-3 and EN 61000-3-2
  • Immunity: EN 55014-2, EN 61000-6-1, EN 61000-6-2 and EN 61000-3-3